File Name:Bullfrog Hot Tub Manual <- [Unlimited PDF].pdf
ENTER SITE »»» DOWNLOAD PDF
CLICK HERE »»» BOOK READER
Size: 3957 KB
Type: PDF, ePub, eBook
Uploaded: 12 May 2019, 12:35
Rating: 4.6/5 from 770 votes.
tatus: AVAILABLE
Last checked: 2 Minutes ago!
eBook includes PDF, ePub and Kindle version
In order to read or download Bullfrog Hot Tub Manual <- [Unlimited PDF] ebook, you need to create a FREE account.
✔ Register a free 1 month Trial Account.
✔ Download as many books as you like (Personal use)
✔ Cancel the membership at any time if not satisfied.
✔ Join Over 80000 Happy Readers
If you are not able to view the manual's please download Adobe Reader. Owner's Manual files are large and may take a few minutes to download. Download the latest version of Adobe Reader Design Your Spa Online and Get a Price Quote Personalize Your Hot Tub with SpaDesign You are unique and your hot tub should fit your unique life. Why would you settle for anything less. SpaDesign allows you to choose the spa model and layout you want, the JetPaks you need, and the color combination that compliments your home and landscape. I was able to remove those jets and just ordered the new thespamaster on Customer Feedback Turn the jet counterclockwise until you reach the stop and then force past the stop. The jet will pop out. NOTE: In this document, the terms “Spa” and “Hot Tub” are U.S. Patents: 7,908,684, 8,661,576, 8,881,321, used interchangeably. Take a moment to read this manual carefully. 8,689,370, 8,869,469, 5,754,989, 5,987,663, Following the instructions in this manual will ensure the safe and 6,000,073, 6,092,246, 6,256,805, 6,543,067.New Zealand Patent: 555112, 334,093 Australia Patent: 737,335 Carefully read this Owner’s Manual before you install your spa. Some jurisdictions without incurring any obligation. Your spa cover comes with a locking system that meets the ASTM F1346-91 Standard for Safety Covers, which when properly used, may satisfy certain fencing and gating requirements. Your spa meets or exceeds all requirements of the Virginia Graeme Baker Pool and Spa Safety Act. Your spa has been tested and either meets or exceeds the UL- 1563 portable spa standard. 3 IMPORTANT SAFETY INSTRUCTIONS Save these instructions 10. WARNING: To Reduce the Risk of Injury: Safety Instructions a. Water temperature in a spa should never exceed 104?F (40 ? C). Water temperatures between 100. F (38?C) and When installing and using this electrical equipment, basic safety 104?F (40?C) are considered safe for a healthy adult. https://domprirody.com/userfiles/cpu-317-2dp-manual.xml
bullfrog hot tub manual, bullfrog hot tub troubleshooting, bullfrog hot tub specs, bullfrog hot tub owners manual, bullfrog spa hot tub manual, bullfrog hot tub manual, bullfrog hot tub manual, bullfrog hot tub manual, bullfrog hot tub owners manual.
Water precautions should always be followed, including the following: temperature in excess of 104. F (40? C) may be harmful to your health. Pregnant women or women children to use this product unless closely supervised at all that could be pregnant should consult a physician and times.Some medications may induce caution must be exercised to prevent unauthorized access by drowsiness while other medication may affect heart rate, children.The suction fittings in the DISEASES SHOULD NOT USE A SPA OR HOT TUB.Should the need arise to replace the suction fittings or 12. WARNING: TO AVOID INJURY, EXERCISE the pump, be sure that the flow rates are compatible. Never operate the spa if the suction fittings are broken or missing. CARE WHEN ENTERING OR EXITING THE SPA Do not replace a suction fitting with one rated less than the flow rate marked on the original suction fitting. OR HOT TUB. NEVER DIVE OR JUMP INTO THE 7. DANGER: Risk of Electric Shock. As per UL SPA. requirements (U.S.), install spa at least 5 feet (1.5m) from all 13. WARNING: DO NOT USE A SPA OR HOT metal surfaces. A spa may be installed within 5 feet (1.5m) of metal surfaces if each metal surface is permanently connected TUB IMMEDIATELY FOLLOWING STRENUOUS by a minimum of No. 8 AWG (8.4mm2) solid copper conductor to the wire connector on the terminal box that is EXERCISE.Do not permit any SPA OR HOT TUB MAY BE HARMFUL TO YOUR electrical appliances, such as a light, telephone, radio, or television within 5 feet (1.5m) of the spa. These units DO HEALTH. NOT have an integral ground fault circuit interrupter. The installation of an integral ground fault circuit interrupter 15. CAUTION: MAINTAIN WATER CHEMISTRY MUST be completed by a qualified Electrician and must meet all applicable electrical codes. IN ACCORDANCE WITH MANUFACTURER’S 9. For Cord-Connected units: INSTRUCTION. a. Replace damaged cord immediately. 16. CAUTION: ADEQUATE DRAINAGE MUST BE b. Do not bury cord. c. http://vitraze.skloart.cz/media/upload/upload/cpu-315f-2-dp-manual.xml
Connect to grounded, grounding-type receptacle only. PROVIDED IF THE EQUIPMENT IS TO BE INSTALLED IN A SPAVAULT OR BELOW GROUND LEVEL. 17. WARNING: Risk of Fatal Hyperthermia. Hyperthermia occurs when the internal temperature of the body reaches a level several degrees above the normal body temperature of 98.6? F (37? C).The symptoms of Hyperthermia include dizziness, lethargy, drowsiness, and fainting. The effects of Hyperthermia include: 29. WARNING: This appliance is not intended for use by a. Unawareness of impending hazard young children or unhealthy persons without supervision. b. Failure to perceive heat c. Failure to recognize the need to exit the spa 30. WARNING: Before obtaining access to supply d. Physical inability to exit the spa e. Fetal damage in pregnant women terminals, all supply circuits must be disconnected. f. Unconsciousness and danger of drowning 31. WARNING: Risk of Injury or Accidental Drowning: 18. WARNING: Risk of Children Drowning. It is suggested to always installed; these parts serve as a barrier against bodily keep the spa cover securely fastened when not in use. This will entrapment against the filter suction fitting(s).If cover is damaged it should be replaced. 32. CAUTION: Test the GFCI or RCD ( Residual 19. WARNING: Risk of Drowning. Use caution when Current Device) before each use of the spa.CAUTION: Risk of Injury. Young children should 33. A green-colored terminal or a terminal marked G, GR, always be supervised so that they do not play in or around the Ground, Grounding or the international grounding symbol spa.To reduce the risk of electric shock, this terminal must be 21. WARNING: Keep all glassware and other breakable connected to the grounding means provided in the electric supply service panel with a continuous copper wire equivalent objects away from the spa area. http://dev.pb-adcon.de/node/20733
At least two lugs marked “BONDING LUGS” are provided high concentrations of ozone and long-term inhalation of low on the external surface or on the inside of the supply terminal concentrations of ozone can cause serious physiological effects.CAUTION: Unauthorized Access. Secure the spa area or hot tub to these terminals with an insulated or bare copper conductor not smaller than No. 6 AWG. against unauthorized access. Make sure all spa barriers (fences, enclosures, etc.) meet all applicable national and local codes. 35. All field-installed metal components such as rails, ladders, Keep spa cover on and locked when it is not being used.CAUTION: Risk of Damage to Spa or Equipment. By (3m) of the spa or hot tub must be bonded to the equipment grounding bus with copper conductors not smaller than No.Never block the air vents that lead to the spa’s 36. WARNING: Risk to Infants, Elderly, and Women equipment compartment, doing so may cause the spa to overheat. Planning or Experiencing Pregnancy. Please consult your physician if the above applies to you or anyone using the spa 25. WARNING: Risk of Electric Shock or Death. Do not operate spa during severe weather conditions (e.g. electrical storms, tornadoes, etc.). 26. CAUTION: Non-Approved Accessories. Using accessories not approved by Bullfrog International, LC could void your warranty or cause other problems. Please consult your authorized Bullfrog Spa dealer. 27. CAUTION: Spa Location. Locate your spa on a foundation that can support the maximum filled weight of your spa along with the weight of all the occupants using the spa (see Site Selection and Preparation). Also, locate your spa in an environment that can withstand repeated exposure to water and the possibility of a major spill. 28. CAUTION: Power cords must be replaced only with 5 a special cord assembly available from the Manufacturer, its Service Agent, or similarly qualified persons in order to avoid a hazard. http://asfgrup.com/images/canon-pixma-mp110-manual.pdf
Warning Signs (North REDUCE THE RISK OF ELECTROCUTION 69.1-S America) 1. NEVER PLACE AN ELECTRIC APPLIANCE WITHIN 5 FEET OF SPA Included with the spa is a warning sign to inform users REDUCE THE RISK OF CHILD DROWNING and guest of the risks involved with using a spa. This sign is suitable for indoor and outdoor use. It should 1. SUPERVISE CHILDREN AT ALL TIMES.Step 5: Fill spa until water level reaches the indicator line at IMPORTANT: Do not turn power on to the spa without right of the filter grill. Reinstall the filter cage cap and filter snap cap.IMPORTANT: Never fill the spa with soft water unless an WARNING: Make sure power is off to your spa prior to appropriate mineral supplement is immediately added (see your authorized Bullfrog Spas Dealer). If your water is extremely hard, following spa filling procedure. Failure to do so may result in it is preferable to either dilute the water’s hardness by blending serious injury.Spas Dealer). Note: Images show spa with filter plate removed for clarity. Step 6: Check for leaks: After the spa is filled, check all fittings Under normal circumstances the filter plate should not be and equipment in equipment compartment for signs of leakage removed.Turn on pump(s), once again, check for leakage. If a leak is detected, tighten the fitting by hand. If the Step 2: Remove a filter cage cap.Step 3: Place garden hose inside the inner chamber of the filter. Step 7: Install Cover: The spa cover comes with tie down straps and locking hardware that attaches the cover to the spa or decking. If your dealer did not install the cover, refer to the Cover Installation Instructions included with the cover. Cover locks are an essential component for compliance with the ASTM F1346-91 safety standard for spa covers. 10 Note: The spa cover is an important part of maintaining spa water at the desired temperature. When spa is not in use, place the cover over the spa and attach tie down straps to the locking hardware.
Control System IMPORTANT: Your Bullfrog Spas spa is equipped with one of 3 types of control pads. Be sure to open all valves in the JetPaks and all other jets in the spa before filling to allow as much air as possible to escape from the system during the filling process. For details see “Filling your spa” section. After turning the power on at the main power panel, the control panel display will go through an initializing sequence. This sequence displays information regarding the configuration of the hot tub control. After a few seconds, your control will display a standard status screen with time, jet and light status, temperature status, operation mode, etc. Power Press any button to turn the keypad on. After 30 minutes without activity it will shut off. Priming the Pumps After initial start up, verify that the home status screen appears on the panel. Pumps must be primed directly after filling to ensure correct operation of your spa. To prime the pumps press the “Jets 1” button once to prime in low-speed. After the pump turns on wait a few seconds and then press “Jets 1” again to initiate high-speed operation of Pump 1. The pump has primed when the jets are running with water flowing from the jets. Press the “Jets 1” button again to turn off Pump 1. If your spa is equipped with a second jet pump repeat the priming process for Pump 2 by pressing the “Jets 2” button once to turn on low speed and then a second time to turn Pump 2 on high. Each pump should run for 4-5 minutes at their highest speed to complete priming. Prime each pump separately and turn Water Temperature Lock Time Wi-Fi Desired Temperature Adustment Indicator Indicator Jets 1 Temperature Menu Jets 2 Audio Lighting Screen Menu Contrast Invert Settings Screen Menu Message Center Heating Status Indicator 12 off before priming the next pump. copenhagenpools.com/contents//files/Dr-880-Manual-Pdf.pdf
To prime your A9L jet pumps press the “Jets 1” If you have the A9L model your spa will be equipped with 3 jet From the home status screen you may press the button to pumps. To prime your A9L pumps follow the instructions above rotate the screen 180 degrees for easier viewing from inside the for pumps 1 and 2 and then press the “Jets 3” button to spa.All pumps will have primed when all jets are running at high speed with water flowing from the jets. Adjusting the Set Temperature Once primed, allow pumps to run at high speed for a few minutes before shutting off. The water temperature is displayed in the center of the home status screen. Press the and buttons to set the desired IMPORTANT: Pumps should not be allowed to run without temperature. The set point will appear in blue. After 3 seconds without any change to the set temperature value, the current priming (no water flowing out of the jets) for more than 2 water temperature will reappear. minutes. Under NO circumstances should a pump be allowed to run without priming beyond the end of the 4-5 minute suggested When the set value is lower than the current temperature priming time. Doing so may cause damage to the pump(s) and “Cooling to xx.x” will appear at the bottom of the screen. When cause the system to energize the heater without water flow, the set value is higher than the current temperature, “Heating potentially resulting in an overheat condition. to xx.x” will be indicated. Normally there may be a short delay before the heating starts, during which “Heating suspended” is NOTE: Sometimes momentarily turning the pump off and indicated under the value.Do not do this more than 5 times. If the Spa Settings pump(s) will not prime, shut off the power to the spa and call for service. The settings on the A Series or STIL (A1000) control pad are navigated by the use of the (Settings) button. {-Variable.fc_1_url-
One press gives Once you have completed priming, the home status screen will you access to several menus where you can manage the specific display the set temperature. The system requires approximately settings of your spa. After pressing the Settings button you may 1-2 minutes of water flowing through the heater to determine access a submenu by pressing the associated icon.Weekender, depending on your needs. Touch the Water Care mode name to choose your setting. A confirmation message will Start or Stop Accessories appear to prevent inadvertent modification of spa water care settings. Touch the check icon to confirm your choice or touch To start or stop an accessory (jets, lights, etc.), press the associated the X icon to decline. button. Icons will become animated when their accessory is turned on, and inanimate when turned off.The filtration schedule shown on the A Series or STIL (A1000) To turn on all available spa pumps in one touch press the screen will apply to the main filtration pump. “Logo” button, located to the side of the main control scrreen. Press the button again to turn off all available pumps. Press once to turn above). Spa will remain in Economy mode at all times of lights on and access the light mode menu. Select from “Interior” the day and all days of the week.Use the associated “Settings” menu to Standard - Beginner: In Standard mode the spa will heat to the Set Date and Time of Day set point and filter according to the spa’s standard configuration. Spa will heat to set point at all times and all days of the week. Setting the correct date and time is important for settings to function as expected. Upon restarting your spa adjust the time Energy Savings: In Energy Savings mode the spa temperature format (24 hr.Select “Set Time” to change the hour, minute and time format. Swipe up and down the column you want to change and select Weekender: In Weekender mode the spa temperature set point the desired value.
When done, touch the Settings icon to save. In the Keypad submenu you can change the temperature unit Default Settings: The Default Settings option will restore all settings or the language setting. Water Care modes and schedules to the spa’s default settings. You will be asked to confirm your choice. Modifying Water Care Schedules Change temperature units by touching the “Temperature Units” title and then the desired unit of measurement. To modify a Water Care category, touch the pen icon at the right of the desired Water Care option to open the submenu. Change the language setting by touching the “Language” title and then selecting the desired language. Touch the Economy tab to change the economy setting and Filter cycle tab for the filtration settings (or schedules). To delete a schedule, Standby mode allows you to service your spa. Pumps can be touch the garbage can icon at the right of the desired function stopped for 30 minutes in this mode, and will automatically title. Confirm your action when prompted.You have several possibilities for the schedule (Mon-Fri, weekend, every day, or single days). The The Lock option allows the user to partially or completely lock schedules will be repeated each week. The time and duration the keypad. To lock the keypad select “Lock Settings” and, are set in 30-minute increments. When changes are done, press when asked, select a 4-digit code. The same code will be needed “confirm”. If you don’t want to keep any changes, press “cancel” or to unlock the keypad. To lock the keypad again, you will be use the calendar icon to go back. Ensure that you have selected prompted to select another 4-digit code.The keypad can be unlocked with a universal unlock code (3732) Reminders or by a reset of the keypad. When Full Lock is selected, all functions are locked. In Partial Lock, you may activate accessories, The A Series and STIL (A1000) keypad can be set up to remind but spa settings may not be changed. www.corwell.co.uk/userfiles/files/Dr-7580-Service-Manual.pdf
Each task has its own standard duration, based on normal use, or you may adjust to This screen allows you to connect to a Wi-Fi network such as is fit your specific expected usage.When a CloudControl2 (in.touch 2) module is detected, this Access the Reminders submenu by pressing the Reminders icon network will appear. Please refer to the CloudControl 2 manual in the Settings menu.Maintenance reminders allow you to verify the time left before maintenance is required, as well as to reset the time once a task is Miscellaneous completed.Once you have confirmed, the task timer will be reset. You can also use the When pumps are running, they produce heat that may 14 option “Reset Reminders” to reset all the reminders.When Warm Weather is “OFF” the filtration over- This section displays technical information about the A Series temperature is disabled and your spa filtering will continue even if and STIL (A1000) control software version and applicable the water temperature is high. IMPORTANT: Please do not make changes in this section If you are using a device with Bluetooth technology, it must be unless you are a qualified electrician.Use code 5555 to pair. In this section you can change the low-level configuration, as Speakers settings: Move the sliders to adjust the Balance, Fader well as modify the number of phases and the input current and Subwoofer settings.Once the modification is completed, confirm selection when asked and touch the Settings Source menu: To change the audio source, simply tap on the icon to return to the Settings menu. “Audio Settings” menu and select desired audio source or device. Note that only the sources available on the Premium or Design NOTE: On initial connection the installer is prompted for Line Audio will be displayed in the source menu.The Low-Level setting is selected by the installer. The Phase and Amperage is set automatically. Default Disconnect Bluetooth: If a device with Bluetooth technology is settings should be confirmed by the installer to match the actual connected to the A Series or STIL Audio, you can disconnect it phase and amperage at the spa’s installation location. In rare by pressing the Disconnect button at the bottom of the screen.Use code 5555 to pair. For proper function, place your Bluetooth device within 20 feet (6 meters) of your spa. NOTE: Certain house construction materials and other obstructions can impair Bluetooth connectivity. You may need to experiment with where to place your device for best results. 16 R SERIES (R800) CONTROL PANELS Priming the Pumps After initial start up, verify that the home status screen appears on the panel. Press the “Jets 1” button again to turn off Pump 1. Preparation and Filling If your spa is equipped with a second jet pump repeat the priming process for Pump 2 by pressing the “Jets 2” button once to Fill the spa to its correct operating level. Be sure to open all turn on low speed and then a second time to turn Pump 2 on valves in the JetPaks and all other jets in the spa before filling to high. Each pump should run for 4-5 minutes at their highest allow as much air as possible to escape from the system during speed to complete priming. Prime each pump separately and turn the filling process. After off before priming the next pump.This sequence IMPORTANT: A pump should not be allowed to run displays information regarding the configuration of the hot tub control. After a few seconds, your control will display a standard without priming (no water flowing out of the jets) for more than status screen with time, jet and light status, temperature status, 2 minutes. Under NO circumstances should a pump be allowed to operation mode, etc.Doing so may cause damage to the pump(s) and Power cause the system to energize the heater without water flow, potentially resulting in an overheat condition. Press any button to turn the keypad on. Do not do this more than 5 times. If the pump(s) will not prime, shut off the power to the spa and call for Press for jets service. The system requires approximately is pressed for 60 seconds. Note that if an accessory is not present 1-2 minutes of water flowing through the heater to determine in your spa configuration, its menu will not appear. Refer to and display the correct water temperature.In and heating settings. In depending on your needs and preferences.A check mark will appear within the selected icon to confirm your selected Start or Stop Accessories mode. To start or stop an accessory (jets, lights, etc.), press the associated In the descriptions of each mode below “Economy mode” means button. When an accessory has more than two states, press the button until it reaches the desired state. The filtration schedule shown on the screen will apply to the main filtration pump. If your spa uses a circulation pump configured to Light Operation run 24 hours, the screen will show you the purge setting instead of filtration. The purges are pre-programmed for a fixed number Turn lights on and off using the button. Press again to turn off. Pressing the button repeatedly screen, and only the start time can be modified.Adjusting the Set Temperature Standard - Beginner: In Standard mode the spa will heat to the The water temperature is displayed near the bottom of the home set point and filter according to the spa’s standard configuration.After 3 seconds without any change to the set temperature value, the current Energy Savings: In Energy Savings mode the spa temperature water temperature will reappear. Spa will When the set value is lower than the current temperature heat to normal set point during evening hours and on the “Cooling to xx.x” will appear at the bottom of the screen. When weekend. the set value is higher than the current temperature, “Heating to xx.x” will be indicated. Spa will heat to normal set point during evening hours, Spa Settings every day of the week. The settings on the R Series (R800) control pad are navigated by Weekender: In Weekender mode the spa temperature set point the use of the (Settings) button. Spa will heat to set point your spa. Default Settings: The Default Settings option will restore 18 When using the Settings menu or submenus the screen will all Water Care modes and schedules to the spa’s default settings. Modifying Water Care Schedules stopped. To modify a Water Care mode schedule, use the lighted key Use Key 6 to Cancel the Standby function before the 30 minute period and restart the spa.Press Key 2 again to cycle to each function as expected. Upon restarting your spa adjust the time submenu item. To delete a schedule, press Key 4 (top) when that schedule is selected within a specific mode’s schedule list. Use the and buttons to choose the setting that you wish to adjust, and select it by pressing Key 2. Use the You have several possibilities for setting each schedule (Mon-Fri, and buttons to change the parameters, and key 2 weekend, every day, or single days). The time and duration are set in 30 minute to the main Settings menu. increments. Ensure that you have selected the desired Water Care mode in the main Water Care menu. In this Settings submenu you can change the temperature unit, language, display orientation, and keypad security. Use the and buttons to choose the setting that rinsing the filter, cleaning the filter, changing spa water, and you wish to adjust, and select it by pressing Key 2. Use the 2-year professional maintenance checks.Standby mode You can lock the keypad by selecting one of 3 security levels: Maintenance reminders menu allows you to verify the time left Unlock, Partial lock, or Full lock. The Partial level locks the set before maintenance is required, as well as to reset the time once a point adjustment and many options in the settings menu. The task is completed. Full level locks all keypad functions. To unlock the keypad (either Partial or Full), press and hold the top selection key (Key Use the and buttons to choose the maintenance 4) for 5 seconds.Select it by pressing Key 2. To Miscellaneous reset a reminder once maintenance has been performed select it by pressing Key 2, then confirm by pressing Key 6 when In the Miscellaneous submenu you can change the Warm prompted. When Warm weather is “Off ”, the filtration over your choice. Doing so will reset all maintenance reminders to temperature feature is disabled. This allows the spa to continue default values.Selecting the Standby mode from the maintenance submenu 19 allows you to service your spa. Pumps will stop for 30 minutes, and automatically restart after this time. Once Standby mode has been activated a screen will appear to show that pumps are Configure the main window message center with the Info Audio System Controls (Optional) messages submenu. When set to “Display, all information” messages are displayed without exception. When set to “Hide” Press the (Settings)to access “in.stream 2” player controls. Use code 5555 to pair. Change Track or station functions works with all sources except AUX.Use the and buttons to move to the selection you want Adjusting the volume: Press the Volume Up or the Volume to modify. Use Key 2 to select, and the and buttons to Down key to increase or decrease the volume.Press Key 2 again to confirm. Changing tracks: Use the Last Track and Next Track keys to Please see the techbook for your spa system for details on low- change tracks. Note that in FM mode these functions can be use level settings. Once you have changed the number of phases in to change stations.Please go back in the Settings menu.When you change to low-Level configuration of the pack, all Comfort Line control settings will Fader, Balance and Subwoofer: Fader, Balance and Subwoofer reset (same as Factory reset feature). NOTE: On initial connection the installer is prompted for electrical configurations. The Low-Level setting is selected by the The first time you use your Bluetooth device with the R Series installer. Default Audio system you must first “pair” your device to the spa audio settings should be confirmed by the installer to match the actual system according to the standard pairing functionality of your phase and amperage at the spa’s installation location. In rare specific device. Each device must be paired separately.This code is “5555”.You may need to About experiment with where to place your device for best results. This screen displays technical information about the control system (R800) software on your R Series spa and applicable revisions of the different components of your system. 20 X SERIES SPA CONTROL PANELS Preparation and Filling Priming the Pumps Fill the spa to its correct operating level. Be sure to open all valves After initial start up, verify that the home status screen appears on and jets in the spa before filling to allow as much air as possible the panel. Pumps must be primed directly after filling to ensure to escape from the system during the filling process. For details correct operation of your spa. To prime the pumps press the see “Filling your spa” section. After turning the power on at the main power panel, the control panel display will go through “Jets 1” button once to prime in low-speed. After the pump an initializing sequence. This sequence displays information regarding the configuration of the hot tub control.Press the “Jets 1” button again to turn off Pump 1. If your spa is equipped with a second jet pump Press any button to turn the keypad on. After 30 minutes without activity it will shut off.Each pump should run for 4-5 minutes at their highest speed to complete priming. Prime each pump separately and turn off before priming the next pump.
- Inicie sesión o registrese para enviar comentarios